General description:
Our oxygen compressor booster is strictly according to the standards for the design,production,technicalperformance,reliablity and safety
1.Materialselection:
Safety first,Performance stability”,we choose the best design of cylinder,supportring,
safety valve toensure the safety for user and extend the service life of compressor.
2.Features:
Low speed and heavy load,high effciency and long lifetime of the wearing parts. low noise and light vibration.
One of the industries is used for rough oxygen cutting, which pumps 93% pure oxygen into an oxygen cylinder and cuts scrap metal with acetylene gas.
Application:
One is that the hospital's PSA oxygen generator needs to be pressurized to supply various wards and operating rooms, providing 7-10 kg of line pressure.
the other is that PSA oxygen needs to be stored. The high-pressure container is convenient for mobile use, and the storage pressure is generally 100barg, 150barg, 200barg, or higher 300barg pressure.
inlet pressure 3-4barg and discharge pressure 150barg or 200 barg.
Three or four-stage compression, each stage is equipped with a safety valve, the inlet is equipped with low intake pressure protection, the exhaust end is equipped with high exhaust pressure protection, and each stage has a temperature sensor. If over-temperature and over-pressure, The system will alarm and stop, ensure safe operation, small size, light weight, and forklift parking position at the bottom, which can be easily moved.
The button function indications for each part of the compressor are as follows, designed to be the kind of Tmall style.
Model | Working medium | inlet pressure (Mpa) | outlet pressure (Mpa) | Motor.KW | Flow rate Nm3/hr | Voltage | Cooling way |
15/4-150 | oxygen | 0.3-0.4 | 15 | 11 | 15 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
16/4-150 | oxygen | 0.3-0.4 | 15 | 11 | 16 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
20/4-150 | oxygen | 0.3-0.4 | 15 | 11 | 20 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
25/4-150 | oxygen | 0.3-0.4 | 15 | 11 | 25 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
30/4-150 | oxygen | 0.3-0.4 | 15 | 11 | 30 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
35/4-150 | oxygen | 0.3-0.4 | 15 | 11 | 35 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
40/4-150 | oxygen | 0.3-0.4 | 15 | 15 | 40 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
42/3-150 | oxygen | 0.3-0.4 | 15 | 15 | 42 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
50/4-150 | oxygen | 0.3-0.4 | 15 | 15 | 50 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
50/2-150 | oxygen | 0.3-0.4 | 15 | 18.5 | 50 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
56/3-150 | oxygen | 0.3-0.4 | 15 | 18.5 | 56 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
60/4-150 | oxygen | 0.3-0.4, | 15 | 18.5 | 60 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
90/4-150 | oxygen | 0.3-0.4 | 15 | 30 | 90 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
100/4-150 | oxygen | 0.3-0.4 | 15 | 30 | 100 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
120/4-120 | oxygen | 0.3-0.4 | 15 | 37 | 120 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
150/4-120 | oxygen | 0.3-0.4 | 15 | 45 | 150 | 220V/380V/415V/440V 410V/230v 50/60HZ | water cooling |
Our oxygen compressors have the following features
According to the different working conditions of the customer:
1. Completely 100% oil free, no oil required (depending on the specific model)
2. Oxygen for VPSA PSA and LOX gas source
3.NO pollution, keep the same purity into the gas
4.RELIABLE and high quality, comparable to the American RIX brand.
5. TOP low cost, low maintenance cost, simple operation, just change the piston ring
6. 4000 hours piston ring working life under low pressure conditions, 1500-200O hours working life under high pressure conditions
7.TOP brand motor, can be specially pointed out, just like the SIMENSE brand
8.SUPPLY JAPAN market, Japan's strict approval quality system
9.CE approved to meet the requirements of the EU market
10. According to the customer's specific working conditions, the compressor is designed for single machine compression, two-stage compression, three-stage compression and four-stage compression.
11. Low speed, long life, average speed 260-350RPM,
12. Low noise, average noise below 75dB, can work quietly in the medical field
13, continuous continuous heavy-duty operation, can run stably for 24 hours without stopping
14. Each stage has an interstage safety valve. If the stage is overpressured, the safety valve will take off and release the overpressure gas to ensure the stable operation of the compressor.
15. Each level has a temperature controller. If the temperature between the stages exceeds the standard, the temperature display will sound and light alarm.
If you need 200 bar outlet ,please kindly contact us! some for reference!
Model | Working medium | suction pressure (Mpa,Psig) | Discharge pressure (Mpa,Psig) | Motor.KW | Flow rate Nm3/hr | Voltage | Cooling way | weight | dimension |
1.8/1-150 | oxygen | 0.1,14.3 | 15,2150 | 1.5 | 1.8 |
220V/380V/415V/440V /410V/230V 50/60HZ |
air cooling | 150kgs | 700×650×650 |
1.8/1-200 | oxygen | 0.1,14.3 | 15,2150 | 1.5 | 1.8 | 220V/380V/415V/440V 50/60HZ | air cooling | 150kgs | 700×650×650 |
2.7/1-150 | oxygen | 0.1,14.3 | 15,2150 | 2.2 | 2.7 | 220V/380V/415V/440V 50/60HZ | air cooling | 150kgs | 700×650×650 |
3/4-150 | oxygen | 0.3-0.4,40-60 | 15,2150 | 3 | 3 | 220V/380V/415V/440V 50/60HZ | air cooling | 150kgs | 700×650×650 |
Model | Working medium | inlet pressure (Mpa) | outlet pressure (Mpa) | Motor.KW | Flow rate Nm3/hr | Voltage | Cooling way | pressure riato |
100/3-150 | oxygen | 0.3 | 15,2150 | 37 | 100 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |
100/3-200 | oxygen | 0.3 | 20,2850 | 37 | 100 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |
110/4-150 | oxygen | 0.4 | 15,2150 | 37 | 110 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |
120/8-150 | oxygen | 0.8 | 15,2150 | 30 | 120 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |
120/2-250 | oxygen | 0.2 | 25,3460 | 55 | 120 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |
130/4-150 | oxygen | 0.4 | 15,2150 | 45 | 130 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |
150/4-185 | oxygen | 0.4 | 18.5,2650 | 55 | 150 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |
200/3.5-200 | oxygen | 0.35 | 20,2850 | 55 | 200 | 220V/380V/415V/440V /230v 50/60HZ | Water cooloing | 4 stage |